RNG-100D-SS

Renogy 100W Mono wiring diagram

100W compact rigid mono panel, legacy RNG-100D-SS version with Vmp 18.6V, Voc 22.3V and Isc 5.86A. 1076×509×35mm, 6.5kg, 14 AWG solar leads; 15A maximum series fuse. Check the label because later versions use different voltages.

Nominal voltage
18.6 V
Rated power
100 W
Rated output
5.4 A

Wiring diagram

How the 100W Mono is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Renogy 100W Mono wiring example with 3 components: 100W Mono, Solar controller, House bank. 4 cable connections. Crossings are not junctions.100W Mono + to Solar controller PV +: 1.5 mm² · 7.5 A fuse, 3 m one way. 100W Mono − to Solar controller PV −: 1.5 mm², 3 m one way. Solar controller BATT + to House bank +: 4 mm² · 15 A fuse, 3 m one way. Solar controller BATT − to House bank −: 4 mm², 3 m one way100W Mono + to Solar controller PV +: 1.5 mm² · 7.5 A fuse, 3 m one way100W Mono − to Solar controller PV −: 1.5 mm², 3 m one waySolar controller BATT + to House bank +: 4 mm² · 15 A fuse, 3 m one waySolar controller BATT − to House bank −: 4 mm², 3 m one wayRenogy 100W Mono100W Mono++−−Victron MPPT 75/10. Single-panel, 12 V charging example. Check the actual panel's cold-weather open-circuit voltage, short-circuit current and the controller limits before adapting it.Solar controllerPV +PV +PV −PV −BATT +BATT +BATT −BATT −12 V 200 Ah house bankHouse bank++−−1.5 mm² · 7.5 A fuse1.5 mm²4 mm² · 15 A fuse4 mm²
Renogy 100W Mono wiring example with 3 components: 100W Mono, Solar controller, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

18.6 V panel Vmp

Wire
1.5 mm² · 16 AWG
Example fuse
7.5 A
Design current
5.4 A
Voltage drop
2.1%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Show sizes in AWG

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 7.5 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation, checked 2026-09-29. Manufacturer documentation →

Which RNG-100D-SS does this represent?

This entry represents the 18.6 V Vmp / 22.3 V Voc version. Renogy's manufacturer datasheet archived by Lowe's matches the catalog's 100 W and 5.38 A operating current. It specifies 33 cells, 1076 × 509 × 35 mm, a 6.5 kg panel and 14 AWG output leads, 2 ft long.

Check the label before combining panels. Renogy's Version 3 datasheet uses the same RNG-100D-SS name but lists 20.4 V Vmp, 24.3 V Voc and 4.91 A Imp. Those values describe a different version; this catalog entry retains the earlier specifications.

What limits the array and its protection?

The matching legacy datasheet gives 5.86 A short-circuit current and a 15 A maximum series fuse rating. The latter is a ceiling on module protection, not a recommendation to put a 15 A fuse on every installation. The connector's separate 30 A rating does not raise that ceiling. Check the actual string layout, cable rating and controller instructions when choosing protection.

The panel's Voc temperature coefficient is −0.28%/°C. Its 22.3 V rating is measured at 25 °C cell temperature; cold conditions increase Voc. Calculate the cold-weather voltage of the complete series string before comparing it with the controller's PV limit. The panel's 600 V maximum system rating is not the controller's allowed input voltage.

How should it be connected and mounted?

Use a solar charge controller between the panel and battery. Renogy's installation manual, section 2.2.3 connects the battery to the controller first, then PV, and sets charging parameters for the battery.

Sections 1.3.4, 1.5 and 2.1.2 call for outdoor PV cable, clean and fully engaged connectors, covering the panel before work, and avoiding disconnection under load. Use the existing frame mounting holes and fasteners secured against vehicle vibration. Match the extension cable connectors to the actual fitted connectors; the legacy datasheet calls them “Solar Connectors” without identifying a connector manufacturer.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

100W compact rigid mono panel, legacy RNG-100D-SS version with Vmp 18.6V, Voc 22.3V and Isc 5.86A. 1076×509×35mm, 6.5kg, 14 AWG solar leads; 15A maximum series fuse. Check the label because later versions use different voltages.

Nominal voltage
18.6 V
Rated power
100 W
Rated output
5.4 A
Panel open-circuit voltage
22.3 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

12 A

−

negative · bidi

12 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works