Battery

SSB LS86C 120Ah Lithium Start wiring diagram

12.8V 120Ah lithium starter battery with internal BMS. The 2000A CCA rating lasts 15 seconds; the manufacturer also specifies 360A for 20 minutes, not an unrestricted continuous rating.

Nominal voltage
12.8 V
Capacity
120 Ah

Wiring diagram

How the SSB LS86C 120 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

SSB LS86C 120Ah Lithium Start wiring example with 4 components: SSB LS86C 120, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Fused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one way. Fused DC distribution 1 to DC fridge −: 4 mm², 3 m one way. SSB LS86C 120 + to Battery disconnect A: 4 mm² · 15 A fuse, 3 m one way. Battery disconnect B to Fused DC distribution IN +: 4 mm² · 15 A fuse, 3 m one way. SSB LS86C 120 − to Fused DC distribution IN −: 4 mm², 3 m one wayFused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one wayFused DC distribution 1 to DC fridge −: 4 mm², 3 m one waySSB LS86C 120 + to Battery disconnect A: 4 mm² · 15 A fuse, 3 m one wayBattery disconnect B to Fused DC distribution IN +: 4 mm² · 15 A fuse, 3 m one waySSB LS86C 120 − to Fused DC distribution IN −: 4 mm², 3 m one waySSB LS86C 120Ah Lithium StartSSB LS86C 120++−−Main Battery SwitchBattery disconnectABBlue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Dometic CRX-65 Fridge. This 12 V example uses Dometic's 15 A supply protection and a short 1 m run with 6 mm² cable. Check the manual's voltage-specific cable graph for your route. At 24 V, the specified protection is 7.5 A. Running current and the fuse rating describe different things.DC fridge++−−4 mm² · 15 A fuse4 mm²4 mm² · 15 A fuse4 mm² · 15 A fuse
SSB LS86C 120Ah Lithium Start wiring example with 4 components: SSB LS86C 120, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

View diagram in AWG

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Issue 4/2024), checked 2026-10-01. Manufacturer documentation →

Identify the lithium starting battery

The SSB LS86C is a 12.8 V, 120 Ah LiFePO4 starting battery with an internal BMS. These notes use the exact-model Issue 4/2024 specification, PDF page 1. A matching full installation manual was not found in SSB's public downloads. The specification supports identifying the battery and its published limits; it does not establish compatibility with every engine or alternator.

Keep cranking figures out of continuous sizing

SSB lists 2000 A CCA at −18°C for 15 seconds, up to 2200 A instantaneous discharge for five seconds, and up to 360 A constant discharge for 20 minutes. Each carries a duration. None establishes an unrestricted 2000 A continuous rating.

Crimp therefore leaves the maximum continuous-discharge field unset. Where the planner needs a battery headroom estimate, its generic LiFePO4 fallback is 1C, or 120 A here. This is a software planning assumption, not an SSB rating or a starting-circuit calculation. The existing terminal allowances likewise do not verify the engine's cranking cable, voltage drop or connector capacity. Use the actual starter requirement and duration for that design.

Confirm charging and alternator behavior

The sheet recommends 36–120 A charging and lists 360 A maximum constant charging. Crimp's 100 A charging value lies within the recommended range. The 15.6 V overcharge protection and 15.2 V recovery are BMS thresholds, not charger setpoints. Normal charge voltage and float settings are missing from the retrieved sheet.

Before connecting an alternator, confirm SSB's instructions for the regulator and any BMS interruption of the charging path. A description of conventional charging compatibility does not specify how a particular alternator handles abrupt battery disconnection.

Address temperature and bank limits

The specification explicitly says no low-temperature protection. Its broad “adaptive temperature” range is not a separate validated cold-charging profile. Obtain permissible cell charging temperatures before cold-weather use; do not rely on the BMS to block it.

The published maxima are two units in series and four in parallel. The drawing requires terminal adapters for the illustrated polarity arrangement. The sheet does not provide adapter torque, fuse selection or complete bank installation instructions. Confirm those against the actual battery hardware and engine installation before assembly. See dimensions and issue marking, PDF page 2.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12.8V 120Ah lithium starter battery with internal BMS. The 2000A CCA rating lasts 15 seconds; the manufacturer also specifies 360A for 20 minutes, not an unrestricted continuous rating.

Nominal voltage
12.8 V
Capacity
120 Ah

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

1000 A

−

negative · bidi

1000 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with SSB LS86C 120.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.