RBT12400LFPL-SHBT

Renogy REGO 400Ah LiFePO4 wiring diagram

REGO 12.8V 400Ah heated LiFePO4 with Bluetooth and an Anderson 350 connector. 350A continuous discharge; up to eight matching batteries in parallel, no series connection.

Nominal voltage
12.8 V
Capacity
400 Ah
Maximum discharge
350 A

Wiring diagram

How the 400Ah LFP is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Renogy REGO 400Ah LiFePO4 wiring example with 4 components: 400Ah LFP, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Fused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one way. Fused DC distribution 1 to DC fridge −: 4 mm², 3 m one way. 400Ah LFP + to Battery disconnect A: 4 mm² · 15 A fuse, 3 m one way. Battery disconnect B to Fused DC distribution IN +: 4 mm² · 15 A fuse, 3 m one way. 400Ah LFP − to Fused DC distribution IN −: 4 mm², 3 m one wayFused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one wayFused DC distribution 1 to DC fridge −: 4 mm², 3 m one way400Ah LFP + to Battery disconnect A: 4 mm² · 15 A fuse, 3 m one wayBattery disconnect B to Fused DC distribution IN +: 4 mm² · 15 A fuse, 3 m one way400Ah LFP − to Fused DC distribution IN −: 4 mm², 3 m one wayRenogy REGO 400Ah LiFePO4400Ah LFP++−−Main Battery SwitchBattery disconnectABBlue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Dometic CRX-65 Fridge. This 12 V example uses Dometic's 15 A supply protection and a short 1 m run with 6 mm² cable. Check the manual's voltage-specific cable graph for your route. At 24 V, the specified protection is 7.5 A. Running current and the fuse rating describe different things.DC fridge++−−4 mm² · 15 A fuse4 mm²4 mm² · 15 A fuse4 mm² · 15 A fuse
Renogy REGO 400Ah LiFePO4 wiring example with 4 components: 400Ah LFP, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

View diagram in AWG

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. A0), checked 2026-10-01. Manufacturer documentation →

Identify the REGO connection system

The pictured metal-case battery with integrated cable and gray Anderson connector is the REGO RBT12400LFPL-SHBT, rated 12.8 V, 400 Ah, 5.12 kWh. Renogy's manual directory supplies that exact model; the former RBT400LFP12S-G1 identifier was unsupported. It includes heating and Bluetooth, with LP16 connections for RV-C communication. See manual directory and specifications, page 54.

Respect current and temperature limits

Maximum continuous discharge is 350 A. Charging permits 300 A at 15–50°C, reducing to 200 A at 0–15°C; colder conditions require the manual's heating and current controls. Crimp uses 350 A discharge and a 200 A charging planning value, which is deliberately below the warm-temperature maximum and is not permission to charge at 200 A below 0°C.

Set a compatible LiFePO4 charger to 14.4 V. The BMS can request lower current according to cell voltage and temperature when communications are established. Use its actual permission, not just the catalog maximum. See charging and BMS current requests, pages 34–35 and 42.

Wire the connector and protect branches

The battery supplies 4/0 AWG cable and a gray Anderson 350 connector. The canvas terminals represent the two contacts, not exposed studs. Fully seat the mating connector and use the matching connector color. Connect through the specified REGO combiner system or correctly sized adapter cables and busbars. Protect branch wiring as required by the connected equipment. See power connections, pages 15–19.

Use parallel connection only, with no more than eight matching batteries, equal-length adapter cables and similar battery voltages. Series connection is prohibited. More batteries do not raise a combiner, connector or outgoing cable's own rating.

Commission heating and storage controls

Heating requires more than 15 A stable charging current per battery, starts below 5°C, stops above 10°C and cannot operate below −20°C. Keep heater settings consistent across the bank. Renogy advises disabling heating with unsuitable low-current or PWM sources that make it cycle repeatedly. See heater operation, pages 31–34.

For storage, disconnect the battery from the system and turn it off. The power button alone cannot complete shutdown while the system remains connected. Follow the manual's periodic recharge procedure and inspect connector contacts for corrosion.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

REGO 12.8V 400Ah heated LiFePO4 with Bluetooth and an Anderson 350 connector. 350A continuous discharge; up to eight matching batteries in parallel, no series connection.

Nominal voltage
12.8 V
Capacity
400 Ah
Maximum discharge
350 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

350 A

−

negative · bidi

350 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with 400Ah LFP.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.