Battery

Lifeline GPL-L16T 6V 400Ah AGM wiring diagram

6 V, 400 Ah AGM deep-cycle battery; two matched units in series make 12 V, 400 Ah. M8 terminals at 7.9 Nm. The 80 A charge allowance is not a manufacturer maximum.

Nominal voltage
6 V
Capacity
400 Ah
Maximum discharge
400 A

Wiring diagram

How the GPL-L16T 400Ah AGM is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Lifeline GPL-L16T 6V 400Ah AGM wiring example with 4 components: 6 V battery · bank negative, Matching 6 V battery, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Fused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one way. Fused DC distribution 1 to DC fridge −: 4 mm², 3 m one way. 6 V battery · bank negative + to Matching 6 V battery −: 6 mm², 3 m one way. Matching 6 V battery + to Fused DC distribution IN +: 6 mm² · 15 A fuse, 3 m one way. 6 V battery · bank negative − to Fused DC distribution IN −: 6 mm², 3 m one wayFused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one wayFused DC distribution 1 to DC fridge −: 4 mm², 3 m one way6 V battery · bank negative + to Matching 6 V battery −: 6 mm², 3 m one wayMatching 6 V battery + to Fused DC distribution IN +: 6 mm² · 15 A fuse, 3 m one way6 V battery · bank negative − to Fused DC distribution IN −: 6 mm², 3 m one wayLifeline GPL-L16T 6V 400Ah AGM6 V battery · banknegative++−−Lifeline GPL-L16T 6V 400Ah AGM. Two matching 6 V batteries in series form a 12 V bank. Match chemistry, capacity, age and state of charge.Matching 6 V battery++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Dometic CRX-65 Fridge. This 12 V example uses Dometic's 15 A supply protection and a short 1 m run with 6 mm² cable. Check the manual's voltage-specific cable graph for your route. At 24 V, the specified protection is 7.5 A. Running current and the fuse rating describe different things.DC fridge++−−4 mm² · 15 A fuse4 mm²6 mm²6 mm² · 15 A fuse
Lifeline GPL-L16T 6V 400Ah AGM wiring example with 4 components: 6 V battery · bank negative, Matching 6 V battery, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

View diagram in AWG

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 6-0101 G — 2019-11-26), checked 2026-10-01. Manufacturer documentation →

Build a 12 V bank from 6 V batteries

Lifeline's GPL-L16T product page specifies a 6 V, 400 Ah AGM deep-cycle battery, with capacity rated at C20. Two matched units in series form a 12 V, 400 Ah bank: voltage adds, amp-hour capacity does not. Connect the first battery's positive to the second battery's negative, then use the two remaining outer terminals for the system. The Lifeline bank diagrams, page 15, show this relationship and parallel-string alternatives.

Crimp's 400 A discharge allowance is a sizing assumption, not a manufacturer-published continuous-discharge limit. The technical manual explains discharge capacity as a function of rate and cutoff voltage; the 400 Ah capacity figure alone cannot establish a 400 A terminal or load rating.

Install and protect the bank

For GPL-L16T, the terminal table, page 13, specifies standard M8 copper-alloy threaded inserts and 70 in-lb / 7.9 Nm torque. Fit the correct bolts and lugs, cover exposed positive connections and protect the system cables against short circuits. Confirm whether the battery has optional terminal hardware; do not substitute the different positive terminal used on some 12 V Lifeline models.

Install upright, with at least 0.25 inch between batteries for airflow. Provide ventilation even though AGM batteries do not require added water. Use batteries of the same size and condition, with balanced current paths when strings are paralleled. Lifeline limits charging cable drop to 0.2 V at full output. See installation, page 14.

Set charging voltages for the whole bank

At 25°C, each 6 V battery uses 7.15 ± 0.05 V absorption and 6.65 ± 0.05 V float; a two-battery 12 V bank therefore uses 14.3 ± 0.1 V and 13.3 ± 0.1 V. Apply the manual's temperature compensation. Full charge is indicated when absorption current falls below 0.5% of capacity, or 2 A for a 400 Ah series string. See charging instructions, page 19.

For repeated cycles deeper than 50%, Lifeline recommends a charger capable of at least 0.2C, which is 80 A here. The catalog's 80 A charging field is consequently not an absolute maximum rating. See page 20.

Maintain usable reserve

Size around Lifeline's recommended 50% average discharge depth where service life matters. Recharge fully after use. During storage, boost-charge every 90 days or when resting voltage reaches 6.25 V per battery, following the manual's storage procedure. Measure individual 6 V batteries as well as total bank voltage; a normal total can conceal unequal batteries.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

6 V, 400 Ah AGM deep-cycle battery; two matched units in series make 12 V, 400 Ah. M8 terminals at 7.9 Nm. The 80 A charge allowance is not a manufacturer maximum.

Nominal voltage
6 V
Capacity
400 Ah
Maximum discharge
400 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

400 A

−

negative · bidi

400 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with GPL-L16T 400Ah AGM.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.