Battery

Lion Energy UT1300 wiring diagram

Original Safari UT1300: 12.8 V, 105 Ah LiFePO4 with internal BMS. 150 A continuous discharge, 100 A maximum charging and 45 A standard charging; the catalog keeps an 80 A charge-planning allowance.

Nominal voltage
12.8 V
Capacity
105 Ah
Maximum discharge
150 A

Wiring diagram

How the UT1300 105Ah is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Lion Energy UT1300 wiring example with 4 components: UT1300 105Ah, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Fused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one way. Fused DC distribution 1 to DC fridge −: 4 mm², 3 m one way. UT1300 105Ah + to Battery disconnect A: 4 mm² · 15 A fuse, 3 m one way. Battery disconnect B to Fused DC distribution IN +: 4 mm² · 15 A fuse, 3 m one way. UT1300 105Ah − to Fused DC distribution IN −: 4 mm², 3 m one wayFused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one wayFused DC distribution 1 to DC fridge −: 4 mm², 3 m one wayUT1300 105Ah + to Battery disconnect A: 4 mm² · 15 A fuse, 3 m one wayBattery disconnect B to Fused DC distribution IN +: 4 mm² · 15 A fuse, 3 m one wayUT1300 105Ah − to Fused DC distribution IN −: 4 mm², 3 m one wayLion Energy UT1300UT1300 105Ah++−−Main Battery SwitchBattery disconnectABBlue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Dometic CRX-65 Fridge. This 12 V example uses Dometic's 15 A supply protection and a short 1 m run with 6 mm² cable. Check the manual's voltage-specific cable graph for your route. At 24 V, the specified protection is 7.5 A. Running current and the fuse rating describe different things.DC fridge++−−4 mm² · 15 A fuse4 mm²4 mm² · 15 A fuse4 mm² · 15 A fuse
Lion Energy UT1300 wiring example with 4 components: UT1300 105Ah, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

View diagram in AWG

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Undated manufacturer manual; accessed 2026-10-01), checked 2026-10-01. Manufacturer documentation →

Identify the original Safari UT 1300

This walkthrough uses Lion Energy's archived Safari UT 1300, 12.8 V / 105 Ah / 1344 Wh manual. It matches the original battery generation shown in the catalog. Later Bluetooth versions must be checked against their own documentation. The filename contains 20201216; the document itself prints no revision identifier.

Use operating limits rather than protection trips

The electrical table, page 4, specifies 150 A maximum continuous discharge, 100 A maximum charge, 45 A standard charging current and 14.6 V maximum charging voltage. Crimp's 80 A charging allowance is a conservative planning value, not the manufacturer's maximum. Its 200 A terminal envelope likewise does not raise the battery's 150 A continuous limit.

The table lists overcurrent protection above 150 A for more than 50 seconds and a 10 V low-voltage cutoff. Those are protective responses; design normal operation to remain within the continuous limits and stop before exhausting the battery. The manual recommends keeping sustained charge/discharge at or below 0.5C and discharge depth within 80% to improve life. See page 6.

Wire and secure the battery

Connect the marked positive and negative power terminals with correctly fitted lugs, protected cables and battery-side overcurrent protection. This edition does not provide a verified terminal tightening torque, so obtain the value for the actual terminal hardware before final assembly. Secure the battery and keep it dry; do not assume a later generation's enclosure rating applies.

A protection shutdown does not replace an accessible system disconnect. For a non-responsive battery, the manual describes holding the top button for three seconds. If a short circuit caused the shutdown, remove the fault first and follow the distinct reset sequence on page 5.

Charge and assemble a bank

Charge only within 0–45°C and discharge within −20–55°C. Use a lithium-compatible charger that respects the voltage/current limits; do not enable lead-acid equalization. Independently fully charge each battery before connecting a bank.

The manual permits no more than four batteries in series. Its diagrams show series and parallel arrangements; they do not establish unlimited parallel capacity. Series batteries must charge and discharge together, with no uneven midpoint load. Confirm larger-bank limits with Lion Energy and design balanced current paths and protection. See bank instructions, pages 5–6.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Original Safari UT1300: 12.8 V, 105 Ah LiFePO4 with internal BMS. 150 A continuous discharge, 100 A maximum charging and 45 A standard charging; the catalog keeps an 80 A charge-planning allowance.

Nominal voltage
12.8 V
Capacity
105 Ah
Maximum discharge
150 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

200 A

−

negative · bidi

200 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with UT1300 105Ah.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.