Lewmar Pro-Series 1000 Windlass wiring diagram

Horizontal 12 V Pro-Series 1000 family: 700 W motor, 50 A normal current, 70 A breaker, 114 kg working-load limit and 454 kg maximum pull. Confirm nameplate, gypsy and Pro-Series/Pro-Fish control variant.

Compatible systems
12 V
Rated power
700 W
Continuous draw
50 A

Wiring diagram

How the 1000 windlass is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Lewmar Pro-Series 1000 Windlass wiring example with 3 components: House bank, Battery disconnect, 1000 windlass. 3 cable connections. Crossings are not junctions.Battery disconnect B to 1000 windlass +: 16 mm² · 70 A fuse, 3 m one way. House bank − to 1000 windlass −: 16 mm², 3 m one way. House bank + to Battery disconnect A: 16 mm² · 70 A fuse, 30 cm one wayBattery disconnect B to 1000 windlass +: 16 mm² · 70 A fuse, 3 m one wayHouse bank − to 1000 windlass −: 16 mm², 3 m one wayHouse bank + to Battery disconnect A: 16 mm² · 70 A fuse, 30 cm one way12 V 200 Ah house bankHouse bank++−−Main Battery SwitchBattery disconnectABLewmar Pro-Series 1000 Windlass1000 windlass++−−16 mm² · 70 A fuse16 mm²16 mm² · 70 A fuse
Lewmar Pro-Series 1000 Windlass wiring example with 3 components: House bank, Battery disconnect, 1000 windlass. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
16 mm² · 6 AWG
Example fuse
70 A
Design current
50 A
Voltage drop
2.8%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Show sizes in AWG

Supporting parts

  1. 6.1 m total of 16 mm² (6 AWG) marine cable
  2. Terminations for 16 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 70 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. B10490 issue 2), checked 2026-10-01. Manufacturer documentation →

Identify the Pro-Series 1000

The catalog photo and 700 W/454 kg specifications match the horizontal Pro-Series 1000 family, rather than a vertical V-series windlass. The current Lewmar product page confirms that family and pulling capacity. Read the actual nameplate and gypsy designation before ordering control parts or a rode: “1000” alone is not an installation identifier.

The downloaded manufacturer manual is preserved by Seatronic. Page 2 lists 12 V supply, 50 A normal current, a 70 A breaker and 114 kg working-load limit for the 1000. Maximum pull is 454 kg; it is not the allowable load to hold indefinitely.

Wire through the reversing controls

Page 6 specifies the 70 A breaker, part 68000240, near the battery in a dry accessible location. Pages 7–9 provide different diagrams for the supplied contactor and optional control boxes. Match the diagram to the installed hardware, including the 3 A control fuse where drawn. The two canvas pins summarize this whole supply circuit; do not connect a small rocker switch directly in the motor-current path.

A Pro-Fish conversion changes free-fall operation and some service parts. Do not assume the Pro-Series clutch procedure applies unchanged after conversion.

Account for cable length and voltage drop

Use the model 1000 cable chart on page 6 with the complete battery-to-windlass-and-return route. It provides conductor sizes for several length bands and limits full-run voltage drop to 10%. Check the chosen conductor's ampacity and actual loaded voltage as well. The catalog's 150 A surge is a planning allowance, not a measured or guaranteed manufacturer peak.

Provide chain fall and independent restraint

Section 4 requires a clear vertical rode fall of at least 300 mm and describes deck reinforcement and gypsy alignment. Match chain pitch and rope construction to the fitted gypsy; a nominal chain diameter alone does not establish compatibility.

Use an independent strong point to hold the rode and secure the anchor while travelling. Isolate the breaker before clearing the gypsy or servicing it. Inspect the rode, mounting fasteners and electrical joints periodically, and follow the manual's clutch and emergency-recovery procedures for the actual Pro-Series/Pro-Fish variant.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Horizontal 12 V Pro-Series 1000 family: 700 W motor, 50 A normal current, 70 A breaker, 114 kg working-load limit and 454 kg maximum pull. Confirm nameplate, gypsy and Pro-Series/Pro-Fish control variant.

Compatible systems
12 V
Rated power
700 W
Continuous draw
50 A
Surge current
150 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

160 A

−

negative · input

160 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with 1000 windlass.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.