Power source

Yamaha EF2200iS wiring diagram

Review the Yamaha EF2200iS catalog ratings and AC connection points, then add the generator to your Crimp diagram.

Open this example as a new project. Use your own parts and cable lengths to make the plan yours.

About this terminal map

This page shows a terminal map. Opening it in Crimp starts a new project with the generator placed on its own, ready for you to add the equipment it supplies.

The map identifies line, neutral and protective-earth connections. This page does not calculate an AC cable size or protection rating.

Show sizes in mm²

Wiring diagram

How the EF2200iS is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Yamaha EF2200iS wiring diagram, positive and negative connections between the system bus and the unit, plus AC L, AC N.
Start a diagram with this part

Build it out

Connect it to the rest of your system.

Add EF2200iS to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Rated power
1,800 W

Supporting parts

  1. A lug or terminal to match each post on the part
  2. Strain relief and boots so nothing chafes or shorts
  3. Cable and fuses sized once the whole system is drawn

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

AC L

ac-l

neutral · output

15 A

AC N

ac-n

neutral · output

15 A

AC ⏚

ac-pe

ground · bidi

15 A

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with EF2200iS.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.