MultiPlus-II 12/3000/120-32 230V

Victron MultiPlus-II 12/3000 230V wiring diagram

See the Victron MultiPlus-II 12/3000 230V connection points and wiring example. Open the diagram in Crimp to add your equipment and plan the cables between them.

Open this example as a new project. Use your own parts and cable lengths to make the plan yours.

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

10 ft one way

12 V DC · 230 V AC model

Wire
4/0 AWG · 120 mm²
Example fuse
400 A
Design current
215 A
Voltage drop
1.6%

Sized against ABYC E-11. The design current is a catalog planning estimate for inverter operation at nominal battery voltage, not a measured draw. Actual current changes with load, battery voltage and efficiency; charging uses the same DC paths. The single-path cable result does not verify the manual's parallel conductors. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

230 V AC model, DC planning example only. The manual specifies a 400 A DC fuse and two 50 mm² cables per polarity for 0–5 m runs (two 70 mm² for 5–10 m), using 90°C copper outside closed conduit. Crimp calculates each drawn path as one conductor; its displayed wire does not verify or replace that parallel pair. The starter uses a 400 Ah placeholder bank and pins the manual's fuse rating. Verify actual battery limits, protection and parallel conductors separately. Manufacturer installation manual

Show sizes in mm²

Wiring diagram

How the MultiPlus-II 230V is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

  1. House bank +

    positive connection

    4/0 AWG (120 mm²) · 400 A fuse

    10 ft one way · 215 A design

    To MultiPlus-II 230V DC +

  2. House bank

    negative connection

    2/0 AWG (70 mm²) · unfused return

    10 ft one way · 215 A design

    To MultiPlus-II 230V DC −

Single-path calculation only; parallel cables require manual review.

Victron MultiPlus-II 12/3000 230V: 2 DC connections from the same editable starter, with individual feed, return and supply-lead assumptions. Read the installation notes before adapting this example.

230 V AC model, DC planning example only. The manual specifies a 400 A DC fuse and two 50 mm² cables per polarity for 0–5 m runs (two 70 mm² for 5–10 m), using 90°C copper outside closed conduit. Crimp calculates each drawn path as one conductor; its displayed wire does not verify or replace that parallel pair. The starter uses a 400 Ah placeholder bank and pins the manual's fuse rating. Verify actual battery limits, protection and parallel conductors separately. Manufacturer installation manual

Edit this wiring example

Installation notes

Connections and installation requirements.

Guidance for this model, with sources linked beside the relevant advice.

Verified against the manufacturer's documentation, checked 2026-09-16. Manufacturer documentation →

Which MultiPlus-II 12/3000 230 V is this?

This page covers MultiPlus-II 12/3000/120-32, 230 V AC: a 12 V battery connection, 3000 VA / 2400 W inverter at 25°C, 120 A charger and 32 A transfer switch. Check the exact column in Victron's specifications.

The 120 in the model number is charging current. It does not identify AC voltage. The single 120 V model and 2x120 V model retain separate entries. Switching this page to AWG changes the presentation, not the hardware.

How is the MultiPlus-II 12/3000 230 V wired?

Installation section 4.3 specifies a 400 A DC fuse and two 50 mm² cables per polarity for 0–5 m, increasing to two 70 mm² per polarity for 5–10 m. It calls for 90°C copper outside closed conduit.

Crimp's single-path conductor result does not validate that parallel pair. The editable starter opens a 400 Ah placeholder bank with the fuse rating pinned and this limitation in its notes. Review the physical parallel conductors, actual bank, disconnect and fuse/holder before using the drawing for installation.

What should I bear in mind with the MultiPlus-II 12/3000 230 V?

The DC draw and peak are estimates from rated output power divided by nominal battery voltage and published maximum efficiency. Maximum efficiency is not a guaranteed operating curve; lower battery voltage changes current, and the peak duration is unspecified. The catalog's DC terminal ceiling is a calculation allowance, not a verified connector rating.

The same connected starter supplies the page calculation and editor. Battery capacity alone does not verify discharge, charging acceptance, BMS behavior or fault-current protection. The fuse checker helps collect the missing hardware evidence.

The example covers DC only. AC supply, protective earth, output protection and grounding behavior require separate design under the manufacturer's instructions. The abbreviated AC terminals are not a complete mains pinout.

What do owners and installers say about the MultiPlus-II 12/3000 230 V?

  • A caravan owner's setup question describes conflicting readings from a SmartShunt, VE.Bus dongle and battery BMS after installation. The indexed account establishes the reported symptom, not its cause or a confirmed remedy. A wiring diagram does not verify monitoring settings or charger configuration.

What belongs around the MultiPlus-II 12/3000 230 V?

The SmartShunt and Lynx Distributor examples cover monitoring and branch distribution around the house bank. Select the actual battery protection and disconnect alongside the parallel-cable design.

Build it out

Connect it to the rest of your system.

Add MultiPlus-II 12/3000/120-32 230V to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Compatible systems
12 V
Rated power
2,400 W
Estimated DC draw
215 A
Rated output
120 A
Estimated DC peak (duration unknown)
493 A

Supporting parts

  1. 20 ft total of 4/0 AWG (120 mm²) marine cable
  2. Terminations for 4/0 AWG cable, matched to the equipment's screw terminals, leads or studs
  3. 400 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

This is MultiPlus-II 12/3000/120-32, 230 V AC. DC + and DC − carry inverter discharge and charging. DC current values and terminal ceilings are planning estimates, not connector ratings. AC-in and AC-out-1 are abbreviated logical connections; protective earth, AC-out-2, grounding behavior and AC protection are not modeled. The editable example leaves AC disconnected.

AC IN L

ac-in-l

neutral · input

32 A

AC IN N

ac-in-n

neutral · input

32 A

DC +

dc-pos

positive · input

623 A

DC −

dc-neg

negative · input

623 A

AC OUT 1 L

ac-out-l

neutral · output

45 A

AC OUT 1 N

ac-out-n

neutral · output

45 A

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with MultiPlus-II 230V.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.